- Stok Durumu: Stok Var
- Marka: OEM
- Model: FRM01 Modül
- SKU: RBZ.100.871
FRM01 Multifunction Time Relay
This product is a time-based programmable relay module. It has 20 different ready-made programs. It is used in various time-based electronic control applications such as smart home, automatic control, incubator motor control .
The module has a relay that can drive 220V 10A AC or 30V 10A DC loads. There are 2 time setting ( T1 - T2 ) menus on the device. T1 and T2 can be set to durations between 1-9999 seconds and 270 hours. A 12V-24V adapter can be used to power the device.

Product Usage:
- If you press and hold the Set key, the function selection and programming menu is entered together with the MD led.
- You can select 20 different functions by setting the rightmost 2 digits of the screen with the ± keys. Using the ± keys, the numbers on the screen are increased and decreased. You can make a selection between 01-20.
- SWI provides transition between the 4 digits of the screen.
- After selecting the program number, if the Set key is pressed briefly, the T1 T2 and NX menus are entered in order.
- T1: This is time setting number 1 to be used in the programs. You can make a setting between 0-9999 sec. Some programs use T1 values, some programs use T2 values. Some programs use both time settings. Both time settings may not have an effect in every program.
- T2: This is time setting number 2 to be used in the programs. You can make a setting between 0-9999 sec. Some programs use T1 values, some programs use T2 values. Some programs use both time settings. Both time settings may not have an effect in every program.
- NX: It is used to set the T1 and T2 durations to higher values in cases where the 9999 setting in seconds is not sufficient. It comes with the factory setting set as 0101. If you do not need higher durations, do not make a setting in this menu. It is used as a multiplier for T1 and T2. The first 2 digits of the Nx menu are the multiplier value for T1. The last 2 digits are the multiplier value for T2.
- For example, if T1= 3000 and NX is 0101, the T1 operating time becomes 3000x01= 3000 sec. From the NX menu, these durations are increased by multiplying them as 2 digits each for t1 and t2.
- For example, when T1= 1000 and T2: 2000 and NX is 0501 ; the T1 operating time becomes 1000x05= 5000 sec. T2= 2000x01= 2000 sec will be calculated.
- In this way, the NX multipliers can be set to the highest values as 99 99. In a case where the timer value is also set to 9999 with a multiplier of 99, durations of up to 270 hours will have been set.
- If you press and hold the Set key, it exits the programming mode and the product starts to operate according to the settings. The settings you have made are saved to memory. After a power outage, the settings are read from memory and the relevant program starts to run with its initial values. The state the program had reached during the power outage is not recorded instantaneously. It is important that you know that in a power outage, the program you previously set will start from the beginning with its initial values.
- There is a blue led next to the relay. If this led is on, it means the relay switch is active. A click sound is heard during the opening and closing of the relay switch. If the blue led is blinking but you cannot hear a sound from the relay, it means you are not powering the product with 12V. The device works with 5V but the relay switching on and off operation only starts to occur after supplies of 9-10V.
- During the operation of the product, it cuts the power of the 4-digit indicator screen in order to reduce energy consumption. This does not mean that the product is not working. The durations continue to run in the background. The screen has been turned off only for energy saving. After the Set key is pressed briefly, the screen turns on immediately and the state of the program can be observed.
Product Technical Specifications:
- Operating voltage: DC 12V -24V
- The product also works with 5V. However, since the relay solenoid voltage is 12V, you need to power the product with an adapter of at least above 9V. For testing we applied voltage of up to 27V at the supply input. There was no problem in the operation of the product. We recommend that higher voltages not be applied. If the product has been damaged by you due to high voltage, it does not take us 5-10 sec to understand this.
- There is reverse connection protection on the adapter inputs. If power does not come when you make the connection, reverse the adapter cable ends and connect them.
- Operating current: 0.1A ( Adapters are generally of high power capacity such as 1-2A. With a 1A adapter you can easily run 10 of this product..)
- Time Setting: 1sec - 274.9 hours
- Relay power: 0-30V/10A, AC 0-250V/10A
- Relay service life. 100000 times switching on and off
- If you create a program that will perform very short-term switching on and off, you may consume the life of the relay, which depends on its switching on and off, in a short time. If the relay on the product breaks down, your product will have become unusable.
- Dimensions : 66mm x 41mm x 20mm
- 4 Character 7 segment display
- 4 Control and setting buttons
Input Terminal Connections:
- DC+ : Supply + Terminal
- DC- : Supply – Terminal Ground
- X1 : Signal Detection Input . An external signal can be read by connecting a button etc. ( Voltage between 3V-30V can be applied from the input) There is the possibility of running the device according to this external signal.
Relay Terminal Connections: The common terminal (com) of the relay is switched between the open terminal and the closed terminal.
- NO : Open Terminal
- COM : Common Terminal
- NC : Closed Terminal
Functions:
- Timing Pick
- Timing off
- Timing pull off again
- Timing and then pull off
- Infinite loop timing mode 1
- Infinite loop timing mode 2
- Finite loop timing mode 1
- Finite loop timing mode 2
- Latching relay modes
- Trigger relay modes
- Pull the trigger timing
- Trigger timing off
- Pull the trigger timing then disconnect
- Disconnect and then pull the trigger timing
- Infinite loop timing mode 1
- Infinite loop timing mode 2
- Finite loop timing mode 1
- Finite loop timing mode 2
- Conditioned loop mode 1: Loop with signal, otherwise, loop stops
- Conditioned loop mode 2: Loop with signal, otherwise, loop stops
In the future we can add the descriptions of the other functions according to needs. We are adding a number of Turkish descriptions to the lower part. However, we have not researched the accuracy of these descriptions, which are quotations. We also did not examine whether there are errors in their translation into Turkish.
Package Contents:
- 1 Piece FRM01 Time Relay
*********************************************
Power-on (start-up) delay function section: